BattWiseR-value targets by climate zone, and what it takes to hit them.

floor, climate zone 7, blown fiberglass

Required R-value
R-38= 15.2″ of blown fiberglass
IECC 2021 minimum for a floor in climate zone 7
Climate zone7
Assemblyfloor
Code minimumR-38
blown fiberglass — R per inchlowest R per inch — needs real depth2.5R/in
Thickness needed15.2″
One R-value betterabove code — usually cheap in an attic, expensive in a wallR-48= 19.2″
Climate zone
7
Assembly
floor
Material
blown fiberglass

The number and the thickness

IECC 2021 sets R-38 for a floor in climate zone 7. That is a resistance target, not a thickness — how deep it has to be depends entirely on what you fill it with. In blown fiberglass, it comes to about 15.2 inches.

Check your local code first

IECC 2021 is the reference here, but it is not automatically the law where you live. Plenty of states still enforce the 2009, 2015 or 2018 edition, and some cities require more. The building department decides.

Installation beats the number on the bag

A batt compressed around wiring, or blown insulation that has been walked on, loses a large part of its rated R-value. And air sealing comes first regardless: moving air carries far more heat than conduction does, so an air-sealed assembly at R-38 outperforms a leaky one rated well above it.

Notes

  • IECC 2021 is the reference here. Many states still enforce the 2009, 2015 or 2018 edition, and some cities go above it. Your building department decides, not this table.
  • R-value assumes the insulation is installed without gaps, compression or wind-washing. A batt squeezed around wiring can lose a third of its rated value — installation quality matters more than the last R-5 on paper.
  • Air sealing comes first. An attic at R-60 with unsealed penetrations underperforms an air-sealed R-38, because moving air carries far more heat than conduction through the assembly.