crawlspace wall, climate zone 7, XPS rigid board
Required R-value
R-15= 3″ of XPS rigid board
IECC 2021 minimum for a crawlspace wall in climate zone 7
| Climate zone | 7 |
|---|---|
| Assembly | crawlspace wall |
| Code minimum | R-15 |
| XPS rigid board — R per inchfor continuous exterior insulation | 5R/in |
| Thickness needed | 3″ |
| One R-value betterabove code — usually cheap in an attic, expensive in a wall | R-25= 5″ |
- Climate zone
- 7
- Assembly
- crawlspace wall
- Material
- XPS rigid board
The number and the thickness
IECC 2021 sets R-15 for a crawlspace wall in climate zone 7. That is a resistance target, not a thickness — how deep it has to be depends entirely on what you fill it with. In XPS rigid board, it comes to about 3 inches.
Check your local code first
IECC 2021 is the reference here, but it is not automatically the law where you live. Plenty of states still enforce the 2009, 2015 or 2018 edition, and some cities require more. The building department decides.
Installation beats the number on the bag
A batt compressed around wiring, or blown insulation that has been walked on, loses a large part of its rated R-value. And air sealing comes first regardless: moving air carries far more heat than conduction does, so an air-sealed assembly at R-15 outperforms a leaky one rated well above it.
Notes
- IECC 2021 is the reference here. Many states still enforce the 2009, 2015 or 2018 edition, and some cities go above it. Your building department decides, not this table.
- R-value assumes the insulation is installed without gaps, compression or wind-washing. A batt squeezed around wiring can lose a third of its rated value — installation quality matters more than the last R-5 on paper.
- Air sealing comes first. An attic at R-60 with unsealed penetrations underperforms an air-sealed R-38, because moving air carries far more heat than conduction through the assembly.
Nearby sizes
- crawlspace wall, climate zone 6, XPS rigid board
- crawlspace wall, climate zone 8, XPS rigid board
- crawlspace wall, climate zone 5, XPS rigid board
- basement wall, climate zone 7, XPS rigid board
- slab edge, climate zone 7, XPS rigid board
- floor, climate zone 7, XPS rigid board
- crawlspace wall, climate zone 7, closed-cell spray foam
- crawlspace wall, climate zone 7, polyiso rigid board
- crawlspace wall, climate zone 7, open-cell spray foam